Counting Scales

FT-IR SPECTROMETER

Spectral Range 7800 to 350cm
Resolution Better than 0.85cm (FTS - 510A)
Better than 0.5cm (FTS - 520A)
Wacenumber Precision +0.01cm
Scanning Speed 5-step adjustable for different applications
Signal to noise ratio Better than 15,000:1 (RMS value, at 2100cm, resolution : 4cm Detector: DTGS, 1 minute data collection
Beam Splitter Ge coated kbr
Infraed Source Air-cooled, high efficiency Reflex Sphere module
Detector DTGS

TALK TO US
Counting Scales

Spectrometer - UV SERIES

Model UV-1601
Wavelength 190-1100nm (FTS - 520A)
Wavelength Accuracy +0.3nm
Wavelength Reproducibility < 0.15nm
Optical System Split beam ratio monitoring Double beam
Photometric Accuracy + 0.3%T (0~100%T), + 0.002A (0~0.5A), + 0.004A (0.5A~1A)
Photometric Reproducibility < 0.2% T
Photometric Range -0.3-3.5A
Stray Light < 0.1%T (Nal, 220nm, NaNO2 340nm
Baseline Flatness + 0.002A
Stability <0.001A/30 min. (at 500nm, after warming up)
Light Source Tungsten Halogen Deuterium Lamp
Light Source Switching Auto Switch selectable from 3-5nm to 370nm

TALK TO US
Counting Scales

VISCOSIMETRY - ALPHA SERIES

Code Model Measuring Range (cP) Speed (r.p.m.) Number of Speeds
V 100003 Alpha L 20-2.000.000 0.3 - 100 18
V 100002 Alpha R 100-13.000.000 0.3 - 100 18
V 100001 Alpha H 200-106.000.000 0.3 - 100 18

TALK TO US
Counting Scales

VISCOSIMETRY - SMART SERIES

Model Measuring Range (cP) Speed (r.p.m.) Number of Speeds
VISCOLEAD ONE/ADV L 20 - 2.000.000 0.3 - 100 18
VISCOLEAD ONE/ADV R 100-13.000.000 0.3 - 100 18
VISCOLEAD ONE/ADV H 200-106.000.000 0.3 - 100 18
VISCOLEAD PRO L 20 - 6.000.000 0.01 - 200 54
VISCOLEAD PRO R 100 - 40.000.000 0.01 - 200 54
VISCOLEAD PRO H 200 - 106.000.000 0.01 - 200

TALK TO US
Counting Scales

DIGITAL REFRACTOMETERS

Range Range Accuracy Resolution Built-in
1.3200-1.5800 nD 1.3200-1.7000 nD 0.0001 nD 0.0001 nD Peltier Flow-through
0-95% Brix 0-95% Brix 0.1%Brix 0.1%Brix Thermostat Cell
Range Range Accuracy Resolution Built-in
DR 6000* x x x
DR 6000-F* x x x x
DR 6000-T x x x x
DR 6000-FT x x x x x
DR 6100* x x x
DR 6100-F* x x x x
DR 6100-F x x x
DR 6100-FT x x x x x

TALK TO US
Counting Scales

AUTOMATIC POLARIMETERS

Model P 8000 P 8100 P 8000-T P 8100-T
Measuring method Optical rotation, int. sugar scale, Concentration, spec. rotation, user-defined
Measuring range +90. +259 Z, 0....99.9 g/ml
Measuring units Angle [, Z], conc. [g / 100 ml], user defined
Resolution 0.001 , 0.01 Z, 0.1 g/ml
Accuracy +0.003 +0.002 +0.003 +0.002
+0.01 Z +0.01 Z +0.01 Z +0.01 Z
+0.5g/100ml +0.5g/100ml +0.5g/100ml +0.5g/100ml
Reproducibility 0.002
Measuring time+90 1 sec.
Light Source 1 LED with filter 589 nm
Wavelength 589 nm other optional
Wavelength selection One fixed wavelength
Connection for temperature sensor Special Tube with temperature sensor Pt 100 required
Temperature measurement 0...99.9 C
Temperature resolution +0.2 C
Temperature reading point Tube
Thermostat ____ ____ Peltier Thermostat Peltier Thermostat
Range of temperature control ____ ____ With water, 15...40 C With water, 15...40 C
Accuracy of temperature control ____ ____ +0.2 C +0.2 C
Max. length o tube 220 mm
Sensitivity min 0.1% (OD3)
Calibration Automatic (menu-driven)
Display LCD 5.7", 320 x 240 pixel, color display
Operation Touchscreen
Measured data storage 999 measurements
Interfaces RS-232, USB, Ethernet
Operating voltage 100V/250V ~ 50/60 Hz

TALK TO US
Counting Scales

FEMIBILITY TESTER

model CFT-1 CFT-4
model 2 1
model 286mm 286mm
model 39mm 39mm
model 156mm 156mm
model 10-240r 10-900r
model +1r +1r
model 20-90rpm 25rpm
model +1rpm +1rpm
model 220V / 50Hz / 50W or 100V / 60Hz / 50W 220V / 50Hz / 50W or 100V / 60Hz / 50W
model 370 x 300 x 340mm 300 x 200 x 330mm
model 14 kg 06 kg

TALK TO US
Counting Scales

TABLET HARDNESS TESTER

Hardness Range (2-199.9) B
Hardness Accuracy Max. (+0.05%)
Moving Distance of probe (2-199.9) B
Hardness Range (2-199.9) B

TALK TO US
Counting Scales

PORTABLE HARDNESS TESTER

Model TH 130
Impact device D integrated
Hardness scales HLD, HB, HRC, HRA, HV, HS
Accuracy + 6HLD (760+30HLD)
Memory 99 average readings
Output RS232 to printer
Average surface Roughness of work piece 1.6u (Ra)
Max. Work piece Hardness 900HLD
Min. radius of work piece (convex / concave) Rmin = 50mm (with support ring Rmin = 10mm)
Min. work piece weight 2~5kg on stable support 0.05~2kg with compact coupling
Min. work piece thickness coupled 5mm
Min. thickness of hardness layers 0.8mm
Indentation depth Impact Devices data
Continuous working time 60 h
Power Rechargeable Li-Polymer batteries
Operating temperature 0~40 C
Overall dimensions 155 x 244 x 55mm
Weight 180g

TALK TO US
Counting Scales

TINTOMETER

Model CT - 2
Measurement Range Red : RD. 1-R79.9 Lovibond Unit
Yellow : Y0. 1-Y79.9 Lovibond Unit
Bule : B0.1-B49.9 Lovibond Unit
Neutral : N0.1-N3.9 Lovinond Unit
Minimum Readout 0.1 Lovibond Unit
Whiteboard Reflectivity >80%
Enclosure 10mm 25.4mm 133.4mm
Dimension 530 x 440 x 330 mm
Weight 10 kg

TALK TO US
Counting Scales

MANUAL LAB POLARIMETERS

Model PM - 4 PM - 5 PM - 2A
Measurement Range -180 t0 +180
Scale Value 1
Vernier +0.05
Magnifier 3X
Light Source Sodium Lamp
Wavelength Manual Semiautomatic Automatic
Round Cuvetter 100 or 200mm
Stable Time 10 minutes
Range of Accuracy 0 ~ +180 (+0.05) 0 ~ +180 (0.02) 0~+45 (+0.02)
Power Requirements 220V AC / 50Hz
Dimension (mm) 500 (L) x 135(W) x 330(H)
Weight 6.5 kg

TALK TO US
Counting Scales

ICE FLAKE MAKER

Model CIF-20 CIF-40 CIF-50 CIF-85 CIF-100 CIF-130
Capacity (kg) / 24h 20 40 50 85 100 130
ICE Storage (kg) 10 15 15 25 25 25
Water Cons. (L/H) <0.8 <1.6 <20 <3.5 <4.1 <5.4
Condensation Wind Cooling
Unit Dim. (mm) 300x493x547 CIF-50 380x543x722 CIF-100 548 x 611 x 883
Pkg. Dim. (mm) 377x571x595 CIF-50 457x621x770 CIF-100 625 x 699 x 952
NW (kg) 32 40 40 57 58 62
GW (kg) 36 45 45 62 64 68
Input Power (W) 120 280 280 420 420 478
Refrigerant R 134a R 134a R 134a R 134a R 134a R 134a

TALK TO US
Counting Scales

UNDERBENCH LABORATORY GLASSWARE WASHER

Model LAB 500SC LAB 500SCL LAB 500CL
Std. Elec. connection (Intl.) 230C/~/50Hz 400V/3~+N/50Hz
Opt. elec. connection (USA) 208V/3~+N/60Hz - 220V/~/60Hz
Power 3000 W 5550 W
Pump power 2x250 W 2 x 250 W
Noise 56 db(A) 56 dB (A)
Permitted room temperature +5 C/41 F-+40 C/104 F +5 C/41 F - +40 C/104 F
Dryer Blower
Dryer Heating

TALK TO US
Counting Scales

MELTING-POINT APPARATUS - CMP SERIES

Model CMP 1B CMP 2A / 2
Melting-Point Measurement Range Room Temperature - 300 C Room Temperature - 300 C
Linear Heating Up Rate 0.2, 0.5, 1.0, 1.5, 2, 3, 4, 5 C 1/min. 0.2, 0.5, 1.0, 1.5, 2, 3, 4, 5 C 1/min.
Accuracy <200 C : + 0.5 C; 200 - 300 C : +0.8C <200 C : + 0.5 C; 200 - 300 C : +0.8C
Weight (Gross) 13.5 kg 11.0 kg
Overall Dimensions 490 mm x 430mm x 320mm 510 mm x 380mm x 360mm

TALK TO US